Error code 98
Row module: Target speed cannot be retained
Warning at Drill and Maestro.Drill (98-1)
since version 10.06
Maestro (98-2)
since version 10.05
When does the warning occur?
Specified target speed for the metering motor cannot be achieved.
Does a Drilling error (drilling drop-out) occur?
Yes!
What to do?
- Inspect voltage and motor load.
After what time is the warning repeated?
3 seconds
Is there an audible indication?
3 successive acoustic signals
How is the warning confirmed?
Alarm Maestro: confirm with ESC
Warning message seed drill: not possible until error is remedied
Terms of use
Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.