Error code 93
Row module: Communication error (Slave communication time-out)
Alarm at Drill and Maestro.Drill (93-1)
since version 10.05
Maestro (93-2)
since version 10.05
When does the alarm occur?
Power supply to module is not present or too low.
Motor processor has corrupted or no software.
Motor processor has corrupted or no software.
Does a Drilling error (drilling drop-out) occur?
Yes!
What to do?
- Inspect power supply to module.
- Check fuses in wiring.
- Perform update.
After what time is the alarm repeated?
3 seconds
Is there an audible indication?
3 successive acoustic signals
How is the alarm confirmed?
Press ESC to confirm