Error code 74
Seed/fertiliser flow: Module x failed
Alarm at Drill.Drill (74-1)
since version 10.03
When does the alarm occur?
"HORSCH" has been selected as seed/fertiliser flow monitoring system.
The connection to the seed/fertiliser flow module is interrupted.
The connection to the seed/fertiliser flow module is interrupted.
Does a Drilling error (drilling drop-out) occur?
No.
What to do?
- Check the plug-and-socket connections and wiring to the module.
- Check the electric power supply.
- After module replacement:
- Perform manual addressing of the modules via diagnostics.
After what time is the alarm repeated?
60 sec.
Is there an audible indication?
3 successive audible signals
How is the alarm confirmed?
Press ESC to confirm
Terms of use
Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.