Error code 74


 

Seed/fertiliser flow: Module x failed

Alarm at Drill.

Drill (74-1)

since version 10.03

When does the alarm occur?

"HORSCH" has been selected as seed/fertiliser flow monitoring system.
The connection to the seed/fertiliser flow module is interrupted.

Does a Drilling error (drilling drop-out) occur?

No.

What to do?

  • Check the plug-and-socket connections and wiring to the module.
  • Check the electric power supply.
  • After module replacement:
    • Perform manual addressing of the modules via diagnostics.

After what time is the alarm repeated?

60 sec.

Is there an audible indication?

3 successive audible signals

How is the alarm confirmed?

Press ESC to confirm