Error code 71
Powerpack speed too high!
Warning at Drill and Maestro.Drill (71-1)
since version 10.03
Maestro (71-2)
since version 9.67
When does the warning occur?
Rotary speed outside the permissible range.
Does a Drilling error (drilling drop-out) occur?
No.
What to do?
- Check the limiting values.
- Check the hydraulic oil flow rate.
Is there an audible indication?
single audible signal
How is the warning confirmed?
not possible, until error has been rectified
Terms of use
Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.