Horsch Startseite
Crop protection Hybrid farming

Error code 6


 

Vacuum too low

Warning at Maestro.

Maestro (6-2)

since version 9.65

When does the warning occur?

The set vacuum cannot be complied with. Limiting value depending on fruit parameter

Does a Drilling error (drilling drop-out) occur?

Yes!

What to do?

  • Correct actual value in comparison to nominal value in accordance with fruit parameter?
  • Increase the fan speed.
  • With the vacuum display unchanged, check the function of the sensor.
  • Check the machine configuration: Vacuum sensor yes/no?

Is there an audible indication?

single audible signal

How is the warning confirmed?

not possible, until error has been rectified


Terms of use

Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.

We use cookies to optimize and continuously improve our website for you. By continuing to use the website, you agree to the use of cookies. Further information on cookies can be found in our data protection declaration More