Error code 54
Metering motor x current too high
Warning at Drill and Maestro.Drill (54-1)
since version 9.66
since version 9.66
Maestro (54-2)
since version 9.65
since version 9.65
When does the warning occur?
Is displayed as soon as the current measured over the last minute is higher than 9 A.
Does a Drilling error (drilling drop-out) occur?
No.
What to do?
- Check the rotor for light movement.
- Check the metering housing for mechanical damage.
- Foreign objects present?
- Use bean kit in case of coarse grain seed.
- Check the current consumption of motor.
- Replace the motor.
After what time is the warning repeated?
10 sec.
How is the warning confirmed?
Press ESC to confirm
Terms of use
Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.