Error code 50
Half-width flap: Middle not reached
Alarm at Drill and Maestro.Drill (50-1)
since version 9.67
Maestro (50-2)
since version 9.67
When does the alarm occur?
The valve for the half-width control has not reached the end position.
Does a Drilling error (drilling drop-out) occur?
Yes!
What to do?
- "Linak" has been selected as configuration for half-width control:
- Check the functions of engine and sensor in the diagnostics.
- Check injector/venturi area mechanically (e.g. easy movement, blocked)
- "Linak 2016" has been selected as configuration for half-width control (from SW 10.01):
- No sensor available.
- The position of the half-width flap is measured internally in the motor.
- Verify the predefined values for left, middle, right.
- Check the motor function in the diagnostics.
- Check the injector/venturi area mechanically (e.g. light moving, blocked)
Is there an audible indication?
3 successive audible signals