Horsch Startseite
植物保护 Hybrid farming

Error code 41


 

Rotary speed of right hand rotary cross harrow too low

Alarm at Drill.

Drill (41-1)

since version 9.67
Show older versions

When does the alarm occur?

Monitoring the rotary cross harrows: Rotation speed right

Does a Drilling error (drilling drop-out) occur?

No.

What to do?

  • Check the function of the rotary cross harrow.
  • Check pulse counting in the diagnostics.
  • Check the rotary speed limits/pulses in the configuration.

After what time is the alarm repeated?

10 sec.

Is there an audible indication?

3 successive audible signals

How is the alarm confirmed?

Press ESC to confirm.


Terms of use

Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.

We use cookies to optimize and continuously improve our website for you. By continuing to use the website, you agree to the use of cookies. Further information on cookies can be found in our data protection declaration More