Horsch Startseite
Crop protection Hybrid farming

Error code 40


 

Rotary speed of left hand rotary cross harrow too low

Alarm at Drill.

Drill (40-1)

since version 9.67
Show older versions

When does the alarm occur?

Monitoring the rotary cross harrows: Rotation speed left

Does a Drilling error (drilling drop-out) occur?

No.

What to do?

  • Check the function of the rotary cross harrow.
  • Check pulse counting in the diagnostics.
  • Check the rotary speed limits/pulses in the configuration.

After what time is the alarm repeated?

10 sec.

Is there an audible indication?

3 successive audible signals

How is the alarm confirmed?

Press ESC to confirm.


Terms of use

Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.