Horsch Startseite
Crop protection Hybrid farming

Error code 38


 

Pressure loss in the indicated tank

Warning at Drill and Maestro.

Drill (38-1)

since version 9.65

Maestro (38-2)

since version 9.65

When does the warning occur?

Always takes place when a pressure loss/switching signal is available (depending on the fan).

Does a Drilling error (drilling drop-out) occur?

Yes!

What to do?

  • Check the tank for leaks

Is there an audible indication?

single audible signal

How is the warning confirmed?

not possible, until error has been rectified


Terms of use

Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.