Error code 35
Seed/fertiliser flow: Module failed
Alarm at Drill and Maestro.When does the alarm occur?
"Dickey John" has been selected as seed/fertiliser flow monitoring system.
The connection to the seed/fertiliser flow modulel is interrupted.
The connection to the seed/fertiliser flow modulel is interrupted.
Does a Drilling error (drilling drop-out) occur?
No.
What to do?
- Check the plug-and-socket connection and the wiring to the module.
- Coloured status LED.
- Diagnostics seed/fertiliser flow system according to operating instructions.
After what time is the alarm repeated?
If module fails again after activation.
Is there an audible indication?
3 successive audible signals
How is the alarm confirmed?
Press ESC to confirm