Error code 32
Rotation speed too high
Alarm at Drill and Maestro.Drill (32-1)
Maestro (32-2)
When does the alarm occur?
Fertiliser/seed metering unit: Maximum speed exceeded.
Does a Drilling error (drilling drop-out) occur?
No.
What to do?
- Does the metering rotor match the output quantity?
- Repeat the calibration.
- Check speed range.
After what time is the alarm repeated?
5 sec.
Is there an audible indication?
single audible signal
How is the alarm confirmed?
not possible, until error has been rectified
Terms of use