Horsch Startseite
Crop protection Hybrid farming

Error code 32


 

Rotation speed too high

Alarm at Drill and Maestro.

Drill (32-1)

since version 9.67
since version 9.67
since version 9.67
Show older versions

Maestro (32-2)

since version 9.67
since version 9.67
since version 9.67
Show older versions

When does the alarm occur?

Fertiliser/seed metering unit: Maximum speed exceeded.

Does a Drilling error (drilling drop-out) occur?

No.

What to do?

  • Does the metering rotor match the output quantity?
  • Repeat the calibration.
  • Check speed range.

After what time is the alarm repeated?

5 sec.

Is there an audible indication?

single audible signal

How is the alarm confirmed?

not possible, until error has been rectified


Terms of use

Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.