Fan speed x exceeded

Warning at Drill and Maestro.

Drill (3-1)

since version 9.65

Maestro (3-2)

since version 9.65

When does the warning occur?

Limiting values, which lead to the error message, can be configured. Compliance with the set values is not possible. (no subsequent alarm)

Does a Drilling error (drilling drop-out) occur?

No.

What to do?

  • Reduce the fan speed.
  • Check sensor function, pulse counting in the diagnostics.
  • Sensor position too close, to far away, check.
  • Check the limiting values in the machine configuration (max. 6000 rpm).
  • Check the adjusted pulses.

Is there an audible indication?

single audible signal

How is the warning confirmed?

not possible, until error has been rectified