Error code 28


 

Row computer: electric voltage too low (supply voltage)

Warning at Maestro.

Maestro (28-2)

since version 9.65

When does the warning occur?

The measured voltage on the drive motor of the indicated row is too low. This is frequently caused by a voltage drop in the system, e.g.
- caused by a too high power consumption of the upstream drive motors or
-by a faulty electric connection to the supply source

Does a Drilling error (drilling drop-out) occur?

No.

What to do?

  • Check power supply, plug-and-socket connections between machine computer and seed bar.
  • Installation kit connected to battery?
  • Extrapower (16 rows and more) connected?

Is there an audible indication?

single audible signal

How is the warning confirmed?

not possible, until error has been rectified