Error code 277
Rotary speed of the left drill shaft too low, deviation from the target value
Alarm at Maistro.Maistro (277-3)
since version 10.13
When does the alarm occur?
Drill shaft monitoring is activated.
The left drill shaft speed deviates more than the set limit (shaft speed in the configuration) from the calculated target speed (calculated by the speed/working width per row/target value and seeds per revolution).
The left drill shaft speed deviates more than the set limit (shaft speed in the configuration) from the calculated target speed (calculated by the speed/working width per row/target value and seeds per revolution).
Does a Drilling error (drilling drop-out) occur?
Yes!
What to do?
- Check the set limit for correctness.
- Check the sensor.
- For hydraulic drill shaft drive:
- Check the function of the motor
- Check the transmission ratio
- For ground drive:
- Check the slip of the drive wheel
- Check the transmission ratio.
After what time is the alarm repeated?
30 sec.
Is there an audible indication?
3 successive acoustic signals
How is the alarm confirmed?
Press ESC to confirm
Terms of use
Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.