Horsch Startseite
Crop protection Hybrid farming

Error code 270


 

Checking row addressing: Connection between job computer and two rows interrupted

Warning at Maestro.

Maestro (270-2)

since version 10.12

When does the warning occur?

When checking row addressing it was detected that the connection between the two indicated rows is interrupted.

Does a Drilling error (drilling drop-out) occur?

Yes!

What to do?

  • Check wiring.
  • Restart system.
  • Inspect system for correct wiring and BUS errors.

After what time is the warning repeated?

0 sec.

Is there an audible indication?

Single acoustic signal

How is the warning confirmed?

not possible until error has been rectified


Terms of use

Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.

We use cookies to optimize and continuously improve our website for you. By continuing to use the website, you agree to the use of cookies. Further information on cookies can be found in our data protection declaration More