Error code 266
Checking row addressing: not enough rows
Alarm at Maestro.Maestro (266-2)
since version 10.12
since version 10.12
When does the alarm occur?
When checking row addressing it was detected that fewer rows are connected than have been configured. The number of configured rows is displayed next to the row symbol.
Does a Drilling error (drilling drop-out) occur?
Yes!
What to do?
- Configuration is correct: Check the connection between the rows. If all row modules are connected correctly (if Extra Power is available, it must be connected), the electronics LED of the row module must light continuously.
- If configuration is correct and the connection between the rows is correct, then perform addressing (press the checkmark button).
- Configuration is not correct (machine was converted): Press the setting wrench button. Configure the correct number of rows.
- If nothing is to be changed, press the cross button. The machine cannot be operated. The blue warning message indicates this fact.
After what time is the alarm repeated?
0 sec.
Is there an audible indication?
none
How is the alarm confirmed?
Confirm with cross, setting wrench or checkmark button