Horsch Startseite
Crop protection Hybrid farming

Error code 262


 

Row module: Communication to job computer interrupted

Alarm at Maestro.

Maestro (262-2)

since version 10.12

When does the alarm occur?

Messages from the job computer do not arrive at the module for several seconds.

Does a Drilling error (drilling drop-out) occur?

Yes!

What to do?

  • Restart the system.
  • Check the wiring between job computer and affected row module.
  • Check module.

After what time is the alarm repeated?

0 sec.

Is there an audible indication?

3 successive acoustic signals

How is the alarm confirmed?

Press ESC to confirm