Error code 261
Check half-width flap
Alarm at Drill and Maestro.Drill (261-1)
since version 10.11
Maestro (261-2)
since version 10.11
When does the alarm occur?
Occurs in case of a blockade of the half-width flap after having started the motor.
Does a Drilling error (drilling drop-out) occur?
Yes!
What to do?
- Explicit information by pop-up. Check half-width flap for damages and remove blockade. In case of damages: replace or repair half-width. It then is obligatory to check the teach values and the positions of the half-width flap. The main switch for the seeding function has to be reactivated independently.
After what time is the alarm repeated?
0 sec.
Is there an audible indication?
3 successive acoustic signals
How is the alarm confirmed?
Press ESC to confirm