Error code 244
Hardware initialisation fault
Alarm at Drill and Maestro.Drill (244-1)
Maestro (244-2)
When does the alarm occur?
BasisLIB returns error when initialising the hardware; the function of at least one of the ports/pins cannot be ensured
Does a Drilling error (drilling drop-out) occur?
Yes!
What to do?
- Restart the system.
- Replace the master job computer.
- If replacing the job computer does not correct the fault, then read the configuration from the master job computer using the Service Tool and contact HORSCH Service.
Is there an audible indication?
Single acoustic signal
How is the alarm confirmed?
Press ESC to confirm
Terms of use
Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.