Error code 238
Half-width flap: high current increase check LINAK flap
Alarm at Drill and Maestro.Drill (238-1)
since version 10.11
Maestro (238-2)
since version 10.11
When does the alarm occur?
Blockade of the half-width motor. It is shut off for protection.
Does a Drilling error (drilling drop-out) occur?
Yes!
What to do?
- After confirmation the flap will be retracted. Then the reference position is accessed again.
- If this occurs repeatedly:
- Check half-width flap for blockades or damages.
- In case of a blockade: remove it.
- In case of a damage: replace flap.
- After the problem has been solved: check correct functioning of the half-width flap.
After what time is the alarm repeated?
0 sec.
Is there an audible indication?
3 successive acoustic signals
How is the alarm confirmed?
Press ESC to confirm
Terms of use
Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.