Error code 237


 

Row module: minimum rotational speed has been reached

Warning at Maestro.

Maestro (237-2)

since version 10.10

When does the warning occur?

The advancing speed is too low for the target plant spacing that has been set. The metering motor is unable to maintain the demanded rotary speed. The nominal plant distance can thus not be maintained.

Does a Drilling error (drilling drop-out) occur?

No.

What to do?

  • Increase driving speed.
  • Select correct metering disc.
  • Check the crop parameter settings (e.g. grains per revolution).
  • Increase target application rate.

Is there an audible indication?

single acoustic signal

How is the warning confirmed?

not possible until error has been rectified