Error code 236
Row module: motor blocked
Alarm at Maestro.Maestro (236-2)
since version 10.10
When does the alarm occur?
Motor moves very sluggishly for a longer period or is blocked.
Does a Drilling error (drilling drop-out) occur?
Yes!
What to do?
- Check motor load.
- Check easy movement of the metering unit.
- Check the securing cotter pin, motor shaft and metering disc spacing according to operating instructions.
- Acknowledge error message, motor restarts.
Is there an audible indication?
3 successive acoustic signals
How is the alarm confirmed?
Press ESC to confirm
Terms of use
Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.