Horsch Startseite
Crop protection Hybrid farming

Error code 235


 

Row module: motor load too high

Warning at Maestro.

Maestro (235-2)

since version 10.10

When does the warning occur?

Motor load to high over extended period. Motor does not switch off.

Does a Drilling error (drilling drop-out) occur?

No.

What to do?

  • Check motor load.
  • Check easy movement of the metering unit.
  • Check the securing cotter pin, motor shaft and metering disc spacing according to operating instructions.

Is there an audible indication?

single acoustic signal

How is the warning confirmed?

not possible until error has been rectified