Horsch Startseite
Crop protection Hybrid farming

Error code 23


 

2. Machine computer failed

Alarm at Drill and Maestro.

Drill (23-1)

since version 9.67
Show older versions

Maestro (23-2)

since version 9.67
Show older versions

When does the alarm occur?

Interruption of connection to the displayed slave computer.

Does a Drilling error (drilling drop-out) occur?

Yes!

What to do?

  • Check the plug-and-socket connections.
  • In case of missing product/tower slaves:
    • Restart Master JR after correcting the error (disconnect ISOBUS for 10 seconds and then reconnect). Product/tower slaves are only recognised again after restarting the master.

After what time is the alarm repeated?

60 sec.

Is there an audible indication?

single audible signal

How is the alarm confirmed?

Press ESC to confirm.


Terms of use

Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.