Error code 218
WorkLight Pro: Power voltage too high
Warning at Drill and Maestro.Drill (218-1)
since version 10.09
Maestro (218-2)
since version 10.09
When does the warning occur?
Power voltage too high. Module no longer operable. Headlight groups are switched off.
Does a Drilling error (drilling drop-out) occur?
No Information.
What to do?
- Check power supply on module. Optimal operating range 10-16 V.
- Check tractor supply.
- Check wiring to module (power supply via job computer (Isobus) or separate cable).
After what time is the warning repeated?
0 sec.
Is there an audible indication?
Single acoustic signal
How is the warning confirmed?
Not possible until error has been rectified
Terms of use
Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.