Error code 211
WorkLight Pro: Short-circuit
Warning at Drill and Maestro.Drill (211-1)
since version 10.09
Maestro (211-2)
since version 10.09
When does the warning occur?
Current between Pins 1 and 2 on module output too high.
Short-circuit (hardware shut-off)
(Cable damaged)
Short-circuit (hardware shut-off)
(Cable damaged)
Does a Drilling error (drilling drop-out) occur?
No.
What to do?
- Inspect cabling. Plug affected headlight group on other output and check again.
- Replace headlight in case of repeated occurrence.
After what time is the warning repeated?
0 sec.
Is there an audible indication?
Single acoustic signal
How is the warning confirmed?
not necessary
Terms of use
Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.