Horsch Startseite
Crop protection Hybrid farming

Error code 211


 

WorkLight Pro: Short-circuit

Warning at Drill and Maestro.

Drill (211-1)

since version 10.09

Maestro (211-2)

since version 10.09

When does the warning occur?

Current between Pins 1 and 2 on module output too high.
Short-circuit (hardware shut-off)
(Cable damaged)

Does a Drilling error (drilling drop-out) occur?

No.

What to do?

  • Inspect cabling. Plug affected headlight group on other output and check again.
  • Replace headlight in case of repeated occurrence.

After what time is the warning repeated?

0 sec.

Is there an audible indication?

Single acoustic signal

How is the warning confirmed?

not necessary