Horsch Startseite
Crop protection Hybrid farming

Error code 210


 

WorkLight Pro: Wire break

Warning at Drill and Maestro.

Drill (210-1)

since version 10.09

Maestro (210-2)

since version 10.09

When does the warning occur?

No headlight is detected on the module output. Cable break (cable damaged)

Does a Drilling error (drilling drop-out) occur?

No.

What to do?

  • Inspect cabling. Plug affected headlight group on other output and check again.
  • If this output also produces a cable break message with the same headlight group, the lines to the headlights or headlight are defective. If the error does not occur at this output, the previously connected output is defective (check module).

After what time is the warning repeated?

0 sec.

Is there an audible indication?

Single acoustic signal

How is the warning confirmed?

not necessary