Horsch Startseite
Crop protection Hybrid farming

Error code 204


 

Row module: CAN bus fault Bus 1

Alarm at Drill and Maestro.

Drill (204-1)

Maestro (204-2)

since version 10.07

When does the alarm occur?

* Error source between the upstream module (right wing) or downstream module (left wing) and signalling module. Components possibly defective: * Module * Plug-and-socket connection * Connecting cable => No communication to adjacent modules.

Does a Drilling error (drilling drop-out) occur?

No.

What to do?

  • Restart system.
  • Address again.
  • Check or replace cables and plug-and-socket connection.
  • Replace module if defective.

Is there an audible indication?

3 successive acoustic signals

How is the alarm confirmed?

Press ESC to confirm


Terms of use

Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.

We use cookies to optimize and continuously improve our website for you. By continuing to use the website, you agree to the use of cookies. Further information on cookies can be found in our data protection declaration More