Error code 202
LINAK overcurrent
Alarm at Drill and Maestro.Drill (202-1)
since version 10.10
Maestro (202-2)
since version 10.10
When does the alarm occur?
Overload of section control motor.
It is shut off for protection.
It is shut off for protection.
Does a Drilling error (drilling drop-out) occur?
Yes!
What to do?
- Check half-width flap for blockage or damages.
- Remove any blockage that may be present.
- Replace flap if damaged.
- Check correct function of half-width flap after problem has been corrected.
- From SW version 10.11:
- Explicit note through popup. Check half-width flap for damage and clear blockage. Replace or repair flap if damaged. After this the teach values and positions of the half-width flap must be absolutely checked. The drill function main switch must be activated again on its own.
Is there an audible indication?
3 successive acoustic signals
How is the alarm confirmed?
Press ESC to confirm