Error code 200


 

Row module: No power supply

Alarm at Drill and Maestro.

Drill (200-1)

Maestro (200-2)

since version 10.07

When does the alarm occur?

No power supply present at row module.
Fuse defective, Wire break or tractor supply too low.

Does a Drilling error (drilling drop-out) occur?

Yes!

What to do?

  • Check the fuse.
  • Check the wiring.
  • Check the voltage on the 2-pin AMP connector of the row module:
    • 1 = -
    • 2 = +

Is there an audible indication?

3 successive acoustic signals

How is the alarm confirmed?

Press ESC to confirm