Error code 2


 

Fan speed x fallen short of

Alarm at Drill and Maestro.

Drill (2-1)

since version 9.67
since version 9.67
Show older versions

Maestro (2-2)

since version 9.67
since version 9.67
since version 9.67
Show older versions

When does the alarm occur?

Fan speed too low.
Limiting values for fan speed, which leads to an error message, can be configured. Compliance with the set values is not possible.

Does a Drilling error (drilling drop-out) occur?

Yes!

What to do?

  • Increase the fan speed.
  • Check sensor function, pulse counting in the diagnostics.
  • Sensor position too close, to far away, check.
  • Check the limiting values in the machine configuration.
  • Check the adjusted pulses.

After what time is the alarm repeated?

15 sec.

Is there an audible indication?

3 successive audible signals

How is the alarm confirmed?

Not necessary! Goes away automatically after 5 sec. The associated warning will remain .