Error code 2
Fan speed x fallen short of
Alarm at Drill and Maestro.Drill (2-1)
Maestro (2-2)
When does the alarm occur?
Fan speed too low.
Limiting values for fan speed, which leads to an error message, can be configured. Compliance with the set values is not possible.
Limiting values for fan speed, which leads to an error message, can be configured. Compliance with the set values is not possible.
Does a Drilling error (drilling drop-out) occur?
Yes!
What to do?
- Increase the fan speed.
- Check sensor function, pulse counting in the diagnostics.
- Sensor position too close, to far away, check.
- Check the limiting values in the machine configuration.
- Check the adjusted pulses.
After what time is the alarm repeated?
15 sec.
Is there an audible indication?
3 successive audible signals
How is the alarm confirmed?
Not necessary! Goes away automatically after 5 sec. The associated warning will remain .