Error code 199
Row module: Motor wire break
Alarm at Drill and Maestro.Drill (199-1)
Maestro (199-2)
since version 10.07
When does the alarm occur?
During a system restart, a motor was detected on this module at least once.
No motor is now detected any longer on the row module output.
=> Wire break (cable damaged/loose).
No motor is now detected any longer on the row module output.
=> Wire break (cable damaged/loose).
Does a Drilling error (drilling drop-out) occur?
Yes!
What to do?
- Check wiring, module and motor.
- Restart the system.
- Replace motor if defective.
Is there an audible indication?
3 successive acoustic signals
How is the alarm confirmed?
Press ESC to confirm
Terms of use
Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.