Error code 198
Row module: Motor overload
Alarm at Drill and Maestro.Drill (198-1)
Maestro (198-2)
since version 10.07
When does the alarm occur?
Torque of the motor too high for extended period.
Motor switches off.
Motor switches off.
Does a Drilling error (drilling drop-out) occur?
Yes!
What to do?
- Check motor load.
- Check metering unit for easy movement.
- Check cotter pin, motor shaft as well as metering disc spacing according to operating instructions.
- Acknowledge error message, motor will then restart.
Is there an audible indication?
3 successive acoustic signals
How is the alarm confirmed?
Press ESC to confirm
Terms of use
Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.