Error code 197
Row module: Motor current too high
Alarm at Drill and Maestro.Drill (197-1)
Maestro (197-2)
since version 10.07
When does the alarm occur?
Current to motor too high.
Motor switches off. Drilling error!
Motor switches off. Drilling error!
Does a Drilling error (drilling drop-out) occur?
Yes!
What to do?
- Inspect cabling.
- Check metering unit for easy movement.
- Check cotter pin, motor shaft as well as metering disc spacing according to operating instructions.
- Acknowledge error message, motor will then restart.
Is there an audible indication?
3 successive acoustic signals
How is the alarm confirmed?
Press ESC to confirm
Terms of use
Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.