Error code 182
Row module: Downpipe sensor signal line defective
Warning at Drill and Maestro.Drill (182-1)
Maestro (182-2)
since version 10.07
When does the warning occur?
Check of signal line with test pulses not successful.
Test of signal line by software takes place automatically when machine is not working.
Cable break (cable damaged).
Test of signal line by software takes place automatically when machine is not working.
Cable break (cable damaged).
Does a Drilling error (drilling drop-out) occur?
No.
What to do?
- Restart system.
- Inspect cabling.
- Replace downpipe sensor if error occurs repeatedly.
Is there an audible indication?
Single acoustic signal
How is the warning confirmed?
Not possible until error has been rectified
Terms of use
Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.