Error code 168
Row module: Fertiliser/seed flow sensor current too high
Warning at Drill and Maestro.Drill (168-1)
Maestro (168-2)
since version 10.07
When does the warning occur?
Current for fertiliser/seed flow sensor too high.
Short-circuit (cable damaged).
Fertiliser/seed flow sensor defective.
Module defective.
Short-circuit (cable damaged).
Fertiliser/seed flow sensor defective.
Module defective.
Does a Drilling error (drilling drop-out) occur?
No.
What to do?
- Inspect cabling.
- Check fertiliser/seed flow sensor.
- Restart system.
- Replace fertiliser/seed flow sensor if defective.
- Replace module if defective.
Is there an audible indication?
Single acoustic signal
How is the warning confirmed?
Not possible until error has been rectified
Terms of use