Error code 164
Row module: Coulter pressure sensor signal current too high
Warning at Drill and Maestro.Drill (164-1)
Maestro (164-2)
since version 10.07
When does the warning occur?
Current on the signal line of the coulter pressure sensor too high (>21 mA).
Does a Drilling error (drilling drop-out) occur?
No.
What to do?
- Inspect cabling.
- Check current on the coulter pressure sensor signal line.
- Replace coulter pressure sensor if defective.
Is there an audible indication?
Single acoustic signal
How is the warning confirmed?
Not possible until error has been rectified