Error code 162
Row module: Coulter pressure valve current too high
Warning at Drill and Maestro.Drill (162-1)
Maestro (162-2)
since version 10.07
When does the warning occur?
* Current on coulter pressure valve too high:
* Short-circuit (cable damaged).
* Coulter pressure valve defective.
* Module defective.
Does a Drilling error (drilling drop-out) occur?
No.
What to do?
- Inspect cabling.
- Check current on coulter pressure valve.
- Replace coulter pressure valve if defective.
- Replace module if defective.
Is there an audible indication?
Single acoustic signal
How is the warning confirmed?
Not possible until error has been rectified