Error code 155
Row module: Downpipe sensor current too low
Warning at Drill and Maestro.Drill (155-1)
Maestro (155-2)
since version 10.07
When does the warning occur?
Current on downpipe sensor too low.
Cable break (cable damaged).
Downpipe sensor defective.
Module defective.
Cable break (cable damaged).
Downpipe sensor defective.
Module defective.
Does a Drilling error (drilling drop-out) occur?
No.
What to do?
- Inspect cabling.
- Check current on downpipe sensor.
- Replace downpipe sensor if defective.
- Replace module if defective.
Is there an audible indication?
Single acoustic signal
How is the warning confirmed?
Not possible until error has been rectified
Terms of use