Error code 152
Row module: Downpipe sensor supply voltage too high
Warning at Drill and Maestro.Drill (152-1)
Maestro (152-2)
since version 10.07
When does the warning occur?
Supply voltage too high.
Module defective.
Module defective.
Does a Drilling error (drilling drop-out) occur?
No.
What to do?
- Check supply voltage on downpipe sensor.
- Optimal operating range 10-16 V.
- Replace module if defective.
Is there an audible indication?
Single acoustic signal
How is the warning confirmed?
Not possible until error has been rectified
Terms of use
Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.