Error code 148
Row module: Motor overload
Alarm at Drill and Maestro.Drill (148-1)
Maestro (148-2)
since version 10.07
When does the alarm occur?
Current to motor too high through mechanical overload.
Motor switches off. Drilling error!
Motor switches off. Drilling error!
Does a Drilling error (drilling drop-out) occur?
Yes!
What to do?
- Check metering unit for easy movement.
- Check cotter pin of motor shaft as well as metering disc spacing according to operating instructions.
Is there an audible indication?
3 successive acoustic signals
How is the alarm confirmed?
Press ESC to confirm
Terms of use