Row module: CAN bus fault Bus 0

Alarm at Drill and Maestro.

Drill (139-1)

Maestro (139-2)

since version 10.07

When does the alarm occur?

* Error source between the upstream module (left wing) or downstream module (right wing) and signalling module. Components possibly defective: * Module * Plug-and-socket connection * Connecting cable => No communication to adjacent modules

Does a Drilling error (drilling drop-out) occur?

No.

What to do?

  • Restart system.
  • Address again.
  • Check / replace cables and plug-and-socket connections.
  • Contact HORSCH Service in case of repeated occurrence.

Is there an audible indication?

3 successive acoustic signals

How is the alarm confirmed?

Press ESC to confirm