Error code 139
Row module: CAN bus fault Bus 0
Alarm at Drill and Maestro.Drill (139-1)
Maestro (139-2)
since version 10.07
When does the alarm occur?
* Error source between the upstream module (left wing) or downstream module (right wing) and signalling module. Components possibly defective:
* Module
* Plug-and-socket connection
* Connecting cable
=> No communication to adjacent modules
Does a Drilling error (drilling drop-out) occur?
No.
What to do?
- Restart system.
- Address again.
- Check / replace cables and plug-and-socket connections.
- Contact HORSCH Service in case of repeated occurrence.
Is there an audible indication?
3 successive acoustic signals
How is the alarm confirmed?
Press ESC to confirm