Error code 138
Row module: CAN bus error Bus 0
Warning at Drill and Maestro.Drill (138-1)
Maestro (138-2)
When does the warning occur?
* Message only appears for individual modules:
=> Error source between upstream and notifying module.
=> Components possibly defective:
* Module
* Plug-and-socket connection
* Connecting cable
* Module addressing faulty
* Message appears for all modules:
* Module addressing faulty
Does a Drilling error (drilling drop-out) occur?
No.
What to do?
- Restart system.
- Address again.
- Check / replace cables and plug-and-socket connections.
- Contact HORSCH Service in case of repeated occurrence.
Is there an audible indication?
Single acoustic signal
How is the warning confirmed?
Not possible until error has been rectified
Terms of use