Error code 130
Minimum quantity
Warning at Maestro.Maestro (130-2)
since version 10.06
When does the warning occur?
Row-individual flow monitoring.
Too little material flow is detected for a specific row.
Too little material flow is detected for a specific row.
Does a Drilling error (drilling drop-out) occur?
Yes!
What to do?
- Inspect the seed/fertiliser hoses for blockage.
- Inspect the seed/fertiliser flow system according to the operating instructions.
Is there an audible indication?
Single acoustic signal
How is the warning confirmed?
Not possible until error has been rectified
Terms of use
Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.