Horsch Startseite
Crop protection Hybrid farming

Error code 116


 

Row module: Short-circuit or motor driver temperature

Warning at Drill and Maestro.

Drill (116-1)

since version 10.05

Maestro (116-2)

since version 10.05

When does the warning occur?

Short-circuit on the motor cable or power driver from the module is too warm.

Does a Drilling error (drilling drop-out) occur?

Yes!

What to do?

  • Check the motor cable for damage.
  • Switch off machine, let it cool down,. execute system new start.
  • In case of repeated occurrence, replace the affected motor cable (a damaged cable cannot necessarily be detected from the outside).

Is there an audible indication?

Single acoustic signal

How is the warning confirmed?

Not possible until error has been rectified


Terms of use

Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.