Error code 112


 

Metering motor overload

Alarm at Drill and Maestro.

Drill (112-1)

since version 10.05

Maestro (112-2)

since version 10.05

When does the alarm occur?

Metering motor overloaded.
Current consumption exceeds the set limiting value.
Mean value of metering unit over 60 seconds above 12A or mean value over 5 seconds above 15A.

Does a Drilling error (drilling drop-out) occur?

Yes!

What to do?

  • Inspect the metering rotor for freedom of movement.
  • Inspect the metering housing for mechanical damage.
  • Foreign objects present? Use bean kit in case of coarse grain seed.
  • Inspect the current consumption of motor.
  • Replace the motor.

Is there an audible indication?

3 successive acoustic signals

How is the alarm confirmed?

Press ESC to confirm