Error code 104
Row module: Communication error (Slave communication time-out)
Alarm at Drill and Maestro.Drill (104-1)
since version 10.05
Maestro (104-2)
since version 10.05
When does the alarm occur?
No communication with seeder row module for at least 5 seconds.
Does a Drilling error (drilling drop-out) occur?
Yes!
What to do?
- Inspect electronics voltage supply.
- Check the wiring.
- Inspect software version.
- For AirVac/AirSpeed:
- Check CAN Enable (PIN 5) on the input of the first and the output of the last module. Operating voltage (approx. 12 V) must be applied to both.
After what time is the alarm repeated?
3 seconds
Is there an audible indication?
3 successive acoustic signals
How is the alarm confirmed?
Press ESC to confirm