Error code 100
Row module: Wire break (motor)
Alarm at Drill and Maestro.Drill (100-1)
since version 10.05
Maestro (100-2)
since version 10.05
When does the alarm occur?
Connection between module and motor interrupted.
Does a Drilling error (drilling drop-out) occur?
Yes!
What to do?
- Inspect connection.
- Replace motor or connecting cables, if necessary.
After what time is the alarm repeated?
3 seconds
Is there an audible indication?
3 successive acoustic signals
How is the alarm confirmed?
Press ESC to confirm