Error code 10
ECU2-BUS error
Warning at Maestro.Maestro (10-2)
since version 9.65
When does the warning occur?
Communication between slave-computer "CAN-OUT" and the connected components is impaired.
Does a Drilling error (drilling drop-out) occur?
No.
What to do?
- For drills:
- If no device is connected to the OUT of the last Slave computer (blind cap on OUT), then the setting in the configuration "Device on ECU2-Bus" must be set to "no".
- If a device is connected to the OUT of the last Slave computer (cable on OUT), then the setting in the configuration "Device on ECU2-Bus" must be set to "yes".
- Check the plug-and-socket connections between the 2nd machine computer output and the connected components.
- For Maestro:
- Check the plug-and-socket connections between the 2nd machine computer output and the connected components.
- If the error occurs again, consult the dealer.
Is there an audible indication?
continuous lined-up audible signals
How is the warning confirmed?
not possible, until error has been rectified
Terms of use
Note: The assistance operations given in the present application may only be carried out observing the safety notes in the operating instructions of the corresponding machine. Compensation claims for damages due to non-observance of the operating instructions are excluded.