Horsch Startseite
Crop protection Hybrid farming

Error code 10


 

ECU2-BUS error

Warning at Maestro.

Maestro (10-2)

since version 9.65

When does the warning occur?

Communication between slave-computer "CAN-OUT" and the connected components is impaired.

Does a Drilling error (drilling drop-out) occur?

No.

What to do?

  • For drills:
    • If no device is connected to the OUT of the last Slave computer (blind cap on OUT), then the setting in the configuration "Device on ECU2-Bus" must be set to "no".
    • If a device is connected to the OUT of the last Slave computer (cable on OUT), then the setting in the configuration "Device on ECU2-Bus" must be set to "yes".
    • Check the plug-and-socket connections between the 2nd machine computer output and the connected components.

  • For Maestro:
    • Check the plug-and-socket connections between the 2nd machine computer output and the connected components.
    • If the error occurs again, consult the dealer.

Is there an audible indication?

continuous lined-up audible signals

How is the warning confirmed?

not possible, until error has been rectified


Terms of use